| Measurement Range | 0–5000 mg/L; 0–50 g/L or extended as required |
|---|---|
| Display Mode | LCD |
| Measurement Unit | mg/L, g/L (auto-switches according to range) |
| Resolution | 0.01 mg/L, 0.1 g/L |
| Basic Error | ±1.0% F.S. |
| Analog Output | 0–20 mA (load resistance < 1.5K Ω); 4–20 mA (load resistance < 750 Ω) |
| 3 Relay Control Contacts | 3A 240 VAC, 3A 28 VDC or 120 VAC |
| Power Supply (optional) | 85–265 VAC±10%, 50±1 Hz, power ≤3W; 9–36 VDC, power ≤3W |
| Dimensions | 144×144×118mm |
| Installation Method | Panel mount (embedded / wall-mounted) |
| Panel Cutout | 138×138mm |
| Operating Environment | Ambient temp -10~60°C; relative humidity ≤90%; no strong magnetic field interference (except earth magnetic field) |
| Applications | Water treatment, environmental monitoring, laboratories, food & beverage, aquaculture |
| Certifications | Manufactured under ISO 9001 QMS · CE/RoHS/FDA compliance varies by model (certificates available upon request) |
The MS6000SG is an online suspended solids concentration meter for biological treatment processes, where knowing the biomass level in the basin matters more than a laboratory number. The instrument covers 0–5000 mg/L or 0–50 g/L, or an extended range on request, and the display switches units automatically between mg/L and g/L according to the range in use. Readings resolve to 0.01 mg/L (0.1 g/L) with a basic error of ±1.0% of full scale, shown on a clear LCD.
The transmitter is built for panel installation: a 144 × 144 × 118 mm housing with a 138 × 138 mm cut-out, one 0–20 mA output (loads to 1.5 kΩ), one 4–20 mA output (loads below 750 Ω), and three relays rated 3 A at 240 VAC for alarms and control. It runs on 85–265 VAC or 9–36 VDC at no more than 3 W and is rated for -10 to 60 °C ambient. Typical duty is monitoring aeration tanks and secondary clarifiers.
What is a suspended solids meter for?
It reports the concentration of suspended biological solids in the water continuously, which lets an operator hold biomass at the level the process needs instead of waiting for laboratory results. Typical points are aeration tanks and secondary clarifier monitoring.
How is the sensor calibrated?
Because mg/L is a derived value, the sensor is matched to your actual sludge: compare the reading with a laboratory suspended solids result from a grab sample of the same point and adjust the calibration factor accordingly.
What do the two unit ranges mean?
The instrument displays 0–5000 mg/L or 0–50 g/L, switching between mg/L and g/L automatically according to the range in use, with resolution of 0.01 mg/L and 0.1 g/L respectively.
What outputs does it provide?
Two analog outputs (0–20 mA and 4–20 mA) for connection to a PLC or recorder, plus three relay contacts rated 3 A at 240 VAC for high-solids alarms, blower staging, or pump control.
Where is it normally installed?
The transmitter mounts in a panel or on a wall using the 144 × 144 × 118 mm housing and 138 × 138 mm cut-out; the sensor is installed in the basin or line being monitored and connected back to the transmitter.
MS6000SG 是一款在线悬浮固体浓度计,面向生化处理工艺——在这里,掌握池内生物量比拿到一个实验室数字更重要。量程 0–5000 mg/L 或 0–50 g/L,也可按需扩展;显示按实际使用的量程在 mg/L 与 g/L 之间自动切换。读数分辨率 0.01 mg/L(0.1 g/L),基本误差为满量程的 ±1.0%,清晰的 LCD 显示。
变送器按面板安装设计:144 × 144 × 118 mm 外壳、开孔 138 × 138 mm;一路 0–20 mA 输出(最大 1.5 kΩ 负载)、一路 4–20 mA 输出(负载低于 750 Ω);三路 3 A/240 VAC 继电器用于报警与控制。供电 85–265 VAC 或 9–36 VDC(不超过 3 W),环境温度 -10 至 60 °C。典型应用是曝气池与二沉池的监测。
悬浮固体计是做什么用的?
它连续报告水中悬浮生物固体的浓度,让操作员把生物量保持在工艺需要的水平,而不必等实验室结果。典型监测点是曝气池与二沉池。
传感器怎么标定?
由于 mg/L 是换算值,传感器要与你的实际污泥匹配:用同一监测点的取样实验室悬浮固体结果与读数对照,再相应调整标定系数。
两个单位量程是什么意思?
仪表显示 0–5000 mg/L 或 0–50 g/L,按实际使用的量程在 mg/L 与 g/L 之间自动切换,分辨率分别为 0.01 mg/L 与 0.1 g/L。
提供哪些输出?
两路模拟输出(0–20 mA 与 4–20 mA)用于接 PLC 或记录仪;三路 3 A/240 VAC 继电器触点用于高固体报警、曝气机分级或泵控制。
通常装在哪里?
变送器用 144 × 144 × 118 mm 外壳与 138 × 138 mm 开孔做面板或壁挂安装;传感器安装在被监测的池体或管线上,连接回变送器。
MS6000SG adalah meter konsentrasi padatan tersuspensi online untuk proses pengolahan biologis, di mana mengetahui level biomassa di bak lebih penting daripada angka laboratorium. Instrumen mencakup 0–5000 mg/L atau 0–50 g/L, atau rentang diperluas berdasarkan permintaan, dan layar berpindah unit secara otomatis antara mg/L dan g/L sesuai rentang yang dipakai. Pembacaan beresolusi 0,01 mg/L (0,1 g/L) dengan galat dasar ±1,0% dari skala penuh, ditampilkan pada LCD yang jelas.
Transmitter dirancang untuk pemasangan panel: rumah 144 × 144 × 118 mm dengan potongan 138 × 138 mm, satu output 0–20 mA (beban hingga 1,5 kΩ), satu output 4–20 mA (beban di bawah 750 Ω), dan tiga relay berating 3 A pada 240 VAC untuk alarm dan kontrol. Ia berjalan pada 85–265 VAC atau 9–36 VDC tidak lebih dari 3 W dan dinilai untuk lingkungan -10 hingga 60 °C. Tugas umum adalah memantau tangki aerasi dan clarifier sekunder.
Untuk apa meter padatan tersuspensi?
Ia melaporkan konsentrasi padatan biologis tersuspensi di air secara berkelanjutan, memungkinkan operator menahan biomassa pada level yang dibutuhkan proses tanpa menunggu hasil laboratorium. Titik tipikal adalah tangki aerasi dan pemantauan clarifier sekunder.
Bagaimana sensor dikalibrasi?
Karena mg/L adalah nilai turunan, sensor dicocokkan dengan lumpur aktual Anda: bandingkan pembacaan dengan hasil padatan tersuspensi laboratorium dari sampel grab titik yang sama dan sesuaikan faktor kalibrasi.
Apa arti dua rentang unit itu?
Instrumen menampilkan 0–5000 mg/L atau 0–50 g/L, berpindah antara mg/L dan g/L otomatis sesuai rentang yang dipakai, dengan resolusi masing-masing 0,01 mg/L dan 0,1 g/L.
Output apa yang disediakannya?
Dua output analog (0–20 mA dan 4–20 mA) untuk koneksi ke PLC atau perekam, plus tiga kontak relay berating 3 A pada 240 VAC untuk alarm padatan tinggi, penahapan blower, atau kontrol pompa.
Di mana biasanya dipasang?
Transmitter dipasang di panel atau dinding memakai rumah 144 × 144 × 118 mm dan potongan 138 × 138 mm; sensor dipasang di bak atau jalur yang dipantau dan dihubungkan kembali ke transmitter.
MS6000SG là máy đo nồng độ chất rắn lơ lửng trực tuyến cho quy trình xử lý sinh học, nơi biết mức sinh khối trong bể quan trọng hơn một con số phòng thí nghiệm. Thiết bị bao phủ 0–5000 mg/L hoặc 0–50 g/L, hoặc dải mở rộng theo yêu cầu, và màn hình tự động chuyển đơn vị giữa mg/L và g/L theo dải đang dùng. Số đọc phân giải 0,01 mg/L (0,1 g/L) với sai số cơ bản ±1,0% thang đo, hiển thị trên LCD rõ ràng.
Bộ truyền được thiết kế cho lắp đặt panel: vỏ 144 × 144 × 118 mm với lỗ cắt 138 × 138 mm, một ngõ ra 0–20 mA (tải tới 1,5 kΩ), một ngõ ra 4–20 mA (tải dưới 750 Ω), và ba relay định mức 3 A ở 240 VAC cho báo động và điều khiển. Nó chạy bằng 85–265 VAC hoặc 9–36 VDC không quá 3 W và được định mức cho môi trường -10 đến 60 °C. Nhiệm vụ điển hình là giám sát bể sục khí và bể lắng thứ cấp.
Máy đo chất rắn lơ lửng dùng để làm gì?
Nó báo cáo liên tục nồng độ chất rắn sinh học lơ lửng trong nước, giúp người vận hành giữ sinh khối ở mức quy trình cần thay vì chờ kết quả phòng thí nghiệm. Điểm điển hình là bể sục khí và giám sát bể lắng thứ cấp.
Cảm biến được hiệu chuẩn thế nào?
Vì mg/L là giá trị suy ra, cảm biến được khớp với bùn thực tế của bạn: so sánh số đọc với kết quả chất rắn lơ lửng phòng thí nghiệm từ mẫu lấy tay cùng điểm và chỉnh hệ số hiệu chuẩn.
Hai dải đơn vị nghĩa là gì?
Thiết bị hiển thị 0–5000 mg/L hoặc 0–50 g/L, tự chuyển giữa mg/L và g/L theo dải đang dùng, với độ phân giải tương ứng 0,01 mg/L và 0,1 g/L.
Nó cung cấp những ngõ ra nào?
Hai ngõ ra analog (0–20 mA và 4–20 mA) để kết nối PLC hoặc máy ghi, cùng ba tiếp điểm relay định mức 3 A ở 240 VAC cho báo động chất rắn cao, phân cấp quạt hoặc điều khiển bơm.
Thường lắp ở đâu?
Bộ truyền lắp panel hoặc tường bằng vỏ 144 × 144 × 118 mm và lỗ cắt 138 × 138 mm; cảm biến lắp trong bể hoặc đường ống được giám sát và nối về bộ truyền.
MS6000SG เป็นเครื่องวัดความเข้มข้นของแข็งแขวนลอยออนไลน์สำหรับกระบวนการบำบัดทางชีวภาพ ซึ่งการรู้ระดับมวลชีวภาพในถังสำคัญกว่าตัวเลขจากห้องปฏิบัติการ เครื่องมือครอบคลุม 0–5000 มก./ล. หรือ 0–50 ก./ล. หรือช่วงขยายตามคำขอ และจอแสดงผลสลับหน่วยระหว่าง มก./ล. และ ก./ล. โดยอัตโนมัติตามช่วงที่ใช้ ค่าที่อ่านมีความละเอียด 0.01 มก./ล. (0.1 ก./ล.) โดยมีความคลาดเคลื่อนพื้นฐาน ±1.0% ของสเกลเต็ม บนจอ LCD ที่ชัดเจน
ตัวส่งสัญญาณออกแบบสำหรับติดตั้งแผง: ตัวเรือน 144 × 144 × 118 มม. พร้อมรูเจาะ 138 × 138 มม. เอาต์พุต 0–20 mA หนึ่งช่อง (โหลดถึง 1.5 kΩ) เอาต์พุต 4–20 mA หนึ่งช่อง (โหลดต่ำกว่า 750 Ω) และรีเลย์สามชุดพิกัด 3 A ที่ 240 VAC สำหรับสัญญาณเตือนและการควบคุม ทำงานด้วย 85–265 VAC หรือ 9–36 VDC ไม่เกิน 3 W และมีพิกัดสภาพแวดล้อม -10 ถึง 60 °C งานทั่วไปคือการตรวจวัดถังเติมอากาศและถังตกตะกอนรอง
เครื่องวัดของแข็งแขวนลอยใช้ทำอะไร?
รายงานความเข้มข้นของของแข็งชีวภาพแขวนลอยในน้ำอย่างต่อเนื่อง ช่วยให้ผู้ปฏิบัติงานรักษาชีวมวลในระดับที่กระบวนการต้องการโดยไม่ต้องรอผลห้องปฏิบัติการ จุดทั่วไปคือถังเติมอากาศและการตรวจถังตกตะกอนรอง
สอบเทียบเซนเซอร์อย่างไร?
เนื่องจาก mg/L เป็นค่าที่แปลงมา เซนเซอร์ต้องจับคู่กับตะกอนจริงของคุณ: เปรียบเทียบค่าที่อ่านกับผลของแข็งแขวนลอยจากห้องปฏิบัติการของตัวอย่างเก็บจากจุดเดียวกันแล้วปรับตัวประกอบการสอบเทียบ
สองช่วงหน่วยหมายถึงอะไร?
เครื่องมือแสดง 0–5000 มก./ล. หรือ 0–50 ก./ล. สลับระหว่าง mg/L และ g/L อัตโนมัติตามช่วงที่ใช้ โดยความละเอียด 0.01 มก./ล. และ 0.1 ก./ล. ตามลำดับ
มีเอาต์พุตอะไรบ้าง?
เอาต์พุตแอนะล็อกสองช่อง (0–20 mA และ 4–20 mA) สำหรับเชื่อมต่อ PLC หรือเครื่องบันทึก พร้อมหน้าสัมผัสรีเลย์สามชุดพิกัด 3 A ที่ 240 VAC สำหรับสัญญาณเตือนของแข็งสูง การสลับขั้นโบลเวอร์ หรือควบคุมปั๊ม
ปกติติดตั้งที่ไหน?
ตัวส่งสัญญาณติดตั้งบนแผงหรือผนังโดยใช้ตัวเรือน 144 × 144 × 118 มม. และรูเจาะ 138 × 138 มม. เซนเซอร์ติดตั้งในถังหรือท่อที่เฝ้าดูและเชื่อมต่อกลับมายังตัวส่งสัญญาณ
MS6000SG ialah meter kepekatan pepejal terampai dalam talian untuk proses rawatan biologi, tempat mengetahui tahap biojisim dalam kolam lebih penting daripada nombor makmal. Instrumen meliputi 0–5000 mg/L atau 0–50 g/L, atau julat lanjutan atas permintaan, dan paparan menukar unit secara automatik antara mg/L dan g/L mengikut julat yang digunakan. Bacaan beresolusi 0.01 mg/L (0.1 g/L) dengan ralat asas ±1.0% daripada skala penuh, dipaparkan pada LCD yang jelas.
Pemancar direka untuk pemasangan panel: perumah 144 × 144 × 118 mm dengan potongan 138 × 138 mm, satu output 0–20 mA (beban sehingga 1.5 kΩ), satu output 4–20 mA (beban di bawah 750 Ω), dan tiga geganti berpenarafan 3 A pada 240 VAC untuk penggera dan kawalan. Ia berjalan pada 85–265 VAC atau 9–36 VDC tidak lebih daripada 3 W dan dinilai untuk persekitaran -10 hingga 60 °C. Tugas biasa ialah memantau tangki pengudaraan dan penjernih sekunder.
Untuk apa meter pepejal terampai?
Ia melaporkan kepekatan pepejal biologi terampai dalam air secara berterusan, membolehkan pengendali mengekalkan biojisim pada tahap yang diperlukan proses tanpa menunggu keputusan makmal. Titik biasa ialah tangki pengudaraan dan pemantauan penjernih sekunder.
Bagaimana sensor ditentukur?
Oleh kerana mg/L ialah nilai terbitan, sensor dipadankan dengan enap cemar sebenar anda: bandingkan bacaan dengan keputusan pepejal terampai makmal daripada sampel grab titik yang sama dan laraskan faktor penentukuran.
Apakah maksud dua julat unit itu?
Instrumen memaparkan 0–5000 mg/L atau 0–50 g/L, menukar antara mg/L dan g/L secara automatik mengikut julat yang digunakan, dengan resolusi 0.01 mg/L dan 0.1 g/L masing-masing.
Apakah output yang disediakannya?
Dua output analog (0–20 mA dan 4–20 mA) untuk sambungan ke PLC atau perakam, serta tiga sesentuh geganti berpenarafan 3 A pada 240 VAC untuk penggera pepejal tinggi, pemeringkatan blower atau kawalan pam.
Di manakah ia biasanya dipasang?
Pemancar dipasang pada panel atau dinding menggunakan perumah 144 × 144 × 118 mm dan potongan 138 × 138 mm; sensor dipasang dalam kolam atau talian yang dipantau dan disambung semula ke pemancar.
Ang MS6000SG ay isang online suspended solids concentration meter para sa biological treatment process, kung saan mas mahalaga ang pag-alam sa biomass level sa basin kaysa sa numero mula sa laboratoryo. Sinasaklaw ng instrumento ang 0–5000 mg/L o 0–50 g/L, o extended range kapag hiniling, at awtomatikong nagpapalit ng unit ang display sa pagitan ng mg/L at g/L ayon sa range na ginagamit. Ang reading ay may resolution na 0.01 mg/L (0.1 g/L) na may basic error na ±1.0% ng full scale, na ipinapakita sa malinaw na LCD.
Ang transmitter ay dinisenyo para sa panel installation: isang 144 × 144 × 118 mm housing na may 138 × 138 mm cut-out, isang 0–20 mA output (load hanggang 1.5 kΩ), isang 4–20 mA output (load na mas mababa sa 750 Ω), at tatlong relay na may rating na 3 A sa 240 VAC para sa mga alarm at control. Tumatakbo ito sa 85–265 VAC o 9–36 VDC na hindi lalampas sa 3 W at may rating na -10 hanggang 60 °C ambient. Ang karaniwang duty ay pagsubaybay sa aeration tank at secondary clarifier.
Para saan ang suspended solids meter?
Iniuulat nito nang tuloy-tuloy ang konsentrasyon ng suspended biological solids sa tubig, na nagpapahintulot sa operator na panatilihin ang biomass sa antas na kailangan ng proseso sa halip na maghintay ng mga laboratory result. Ang karaniwang punto ay aeration tank at secondary clarifier monitoring.
Paano naka-calibrate ang sensor?
Dahil ang mg/L ay isang derived value, ang sensor ay itinutugma sa inyong aktuwal na sludge: ihambing ang reading sa laboratory suspended solids result mula sa grab sample ng parehong punto at ayusin ang calibration factor nang naaayon.
Ano ang ibig sabihin ng dalawang unit range?
Ang instrumento ay nagpapakita ng 0–5000 mg/L o 0–50 g/L, na awtomatikong lumilipat sa pagitan ng mg/L at g/L ayon sa range na ginagamit, na may resolution na 0.01 mg/L at 0.1 g/L ayon sa pagkakasunod.
Anong mga output ang ibinibigay nito?
Dalawang analog output (0–20 mA at 4–20 mA) para sa koneksyon sa PLC o recorder, plus tatlong relay contact na may rating na 3 A sa 240 VAC para sa high-solids alarm, blower staging, o pump control.
Saan karaniwang naka-install ito?
Ang transmitter ay naka-mount sa panel o dingding gamit ang 144 × 144 × 118 mm housing at 138 × 138 mm cut-out; ang sensor ay naka-install sa basin o line na mino-monitor at konektado pabalik sa transmitter.