Dissolved Oxygen Saturation Calculator
Values below are the FAO freshwater reference series. A dissolved oxygen reading only means something next to the saturation value for that water at that temperature and pressure. 8.2 mg/L means something different at 15°C than at 30°C, and at sea level than at 1500 m. This calculator gives you the ceiling so the reading can be read as a percentage — which is the number that actually tracks biological demand.
Saturation and percent saturation
Result
Why the same mg/L reading means different things
Oxygen solubility falls as water warms and as altitude rises. At sea level and 20°C, freshwater saturates near 9.1 mg/L. At 30°C the same water saturates near 7.6 mg/L. A plant reading 7.8 mg/L is at 100% saturation in late summer and at 86% in midwinter — same concentration, very different biological state.
Reporting saturation as a percentage removes that ambiguity, and it is what running an aeration basin on DO control actually requires.
Saturation values by altitude (freshwater)
| Altitude (m) | Saturation at 20°C (mg/L) | Saturation at 30°C (mg/L) |
|---|---|---|
| 0 | 9.08 | 7.54 |
| 300 | 8.76 | 7.27 |
| 600 | 8.46 | 7.01 |
| 900 | 8.16 | 6.77 |
| 1200 | 7.88 | 6.53 |
| 1500 | 7.61 | 6.29 |
| 1800 | 7.34 | 6.07 |
| 2100 | 7.08 | 5.85 |
Saturation deficit and what it means for aeration
The saturation deficit is the gap between what the water could hold and what it currently holds, expressed in mg/L. It is the oxygen mass that aeration equipment has to transfer to reach the target setpoint. Multiplying the deficit by the flow rate gives the oxygen load in kg/day, which is the number that sizes a blower.
Because deficit shrinks as temperature rises, the same aeration basin needs more air in summer than in winter for the same saturation target. Fixed-rate blowers that are adequate in winter under-aerate in summer, and the resulting low DO shows up as filamentous bulking.
Accuracy of the altitude correction
The calculator applies the barometric pressure ratio (P − Pᵥ) / (Pₛₑᵇ − Pᵥ), with Pᵥ the water vapour pressure from the Tetens equation, and interpolates the sea-level saturation from standard reference points. Against the FAO freshwater series this matches within 0.02 mg/L up to about 1500 m and within 0.15 mg/L at 2100 m — roughly 2% at extreme inland altitude.
Where a discharge permit or a design document specifies its own table, use that table. This page is a working aid, not the reference of record.
Why aeration tables disagree
Reference tables are published for specific conditions: freshwater at sea level, or 20°C standard atmosphere, or clean water. Salinity reduces solubility — seawater at 35 PSU holds roughly 20% less oxygen than freshwater at the same temperature. Effluent with dissolved solids at 2000 mg/L is measurably between the two. When a permit or a design document specifies a table, match its assumptions or you will be out by a few percent.
Instruments for this measurement
Models shown are representative families, not a complete catalogue. Send us your application, water analysis and installation constraints and we will match instruments to it.
Frequently asked
What is the maximum dissolved oxygen at 20°C?
Why is my DO percentage different at the same mg/L reading?
Does salinity affect oxygen saturation?
Should I control aeration to mg/L or to percent saturation?
Why does my membrane DO probe need frequent service?
This page provides calculation guidance and a screening cross-check. It is not a substitute for the measurement method named in your permit, and values shown are typical ranges rather than guarantees for a particular instrument.