DO100 Pen-type dissolved oxygen meter. Waterproof and battery-powered for aquaculture

Pen-type dissolved oxygen meter. Waterproof and battery-powered for aquaculture, environmental, and food industry on-site applications.
✓ Transparent sourcing — factory-direct price, no markup
Request a Quote WhatsApp Us

Product Specifications

ModelDO100
Measurement Range0.00~20.00mg/L, 0.0~200.00%
Resolution0.01mg/L, 0.1%
Accuracy±2% F.S.
Calibration1 point or 2 points (0% oxygen-free or 100% saturated oxygen)
ElectrodeReplaceable DO electrode (galvanic)
Temperature Measuring Range0~100.0℃/ 32~212℉
Operating Temperature Range0~60.0℃/ 32~140℉
Display20×30mm multi-line LCD display
Temperature CompensationATC automatic / MTC manual
Protection RatingIP67
Power Supply1 × AAA battery
Auto Backlight1 minute
Auto Power Off10 minutes
Dimensions180×40×45mm
Weight90g
ApplicationsWater treatment, environmental monitoring, laboratories, food & beverage, aquaculture
CertificationsManufactured under ISO 9001 QMS · CE/RoHS/FDA compliance varies by model (certificates available upon request)

Overview

The DO100 is a pen-type dissolved oxygen meter aimed at the people who depend on oxygen most: fish and shrimp farmers. It reads oxygen two ways from the same sample — 0.00–20.00 mg/L and 0.0–200.0 % saturation — at 0.01 mg/L / 0.1 % resolution, with ±2 % F.S. accuracy.

The replaceable galvanic DO electrode needs no polarization wait and no routine membrane exchange from the user's side; calibration is a 1- or 2-point procedure against an oxygen-free solution or saturated air. The 90 g pen is IP67-rated and runs on one AAA battery.

Applications

Selection notes

  1. Read both units: mg/L tells you the actual oxygen content for stocking decisions, while % saturation indicates how close the water is to its maximum at the current temperature and salinity.
  2. Calibrate before critical batches: a 1-point calibration on saturated air covers most pond work; use the 2-point procedure (0 % plus 100 %) when you need the full range to be accurate.
  3. Store the galvanic electrode with its protective cap in place and keep the sensing tip wet — a dried-out tip is the most common cause of slow response.

Frequently asked questions

What is the difference between mg/L and % saturation?

mg/L is the weight of oxygen in each liter of water; % saturation compares that value with the theoretical maximum at the current temperature, pressure and salinity. Both views come from the same measurement.

Is the electrode replaceable and does it need a membrane?

The DO100 uses a replaceable galvanic electrode designed so routine membrane exchange is not part of normal use — the electrode itself is the exchange part when it reaches end of life.

What do the two calibration points mean?

The 1-point procedure calibrates against 100 % saturated oxygen (moist air); the optional second point uses a 0 % oxygen-free solution. More points improve accuracy across the range but are not required for every pond check.

Why is DO important before stocking or feeding?

Low dissolved oxygen stresses fish and shrimp, slows growth and can cause mortality at night. A quick pen reading lets you confirm levels are adequate and time aeration before acting.

概述

DO100 是一款笔式溶解氧测量仪,服务最依赖溶解氧的人群:鱼虾养殖户。同一份样品可读出两种氧含量表示——0.00–20.00 mg/L 和 0.0–200.0 % 饱和度——分辨率 0.01 mg/L / 0.1 %,精度 ±2 % F.S.。

可更换的原电池(伽伐尼)式溶解氧电极无需极化等待,日常使用也无需用户更换膜片;校准为 1 点或 2 点程序,对照无氧溶液或饱和空气进行。90 g 笔身防护等级 IP67,单节 AAA 电池供电。

应用场景

选型建议

  1. 同时看两种单位:mg/L 给出实际氧含量供放养决策;% 饱和度则表示在当前温度与盐度下水体距离最大溶氧有多近。
  2. 关键批次前先校准:饱和空气的 1 点校准覆盖大多数池塘作业;需要全量程准确时用 2 点程序(0 % 加 100 %)。
  3. 原电池电极不用时盖好保护帽并保持传感端湿润——干燥的传感端是响应变慢最常见的原因。

常见问题

mg/L 与 % 饱和度有什么区别?

mg/L 是每升水中氧的重量;% 饱和度是把这个值与当前温度、气压和盐度下的理论最大值比较。两种视角来自同一次测量。

电极可更换吗?需要换膜吗?

DO100 采用可更换的原电池式电极,设计上日常使用无需换膜——电极本体寿命到后直接更换电极即可。

两个校准点分别代表什么?

1 点程序用 100 % 饱和氧(潮湿空气)校准;可选的第 2 点用 0 % 无氧溶液。校准点越多全量程越准,但并非每次池塘检测都需要。

为什么放苗或投喂前要关注溶解氧?

低溶解氧会让鱼虾产生应激、生长变慢,夜间甚至导致死亡。笔式快测能让你在行动前确认溶氧是否充足、曝气时机是否合适。

Ikhtisar

DO100 adalah meter oksigen terlarut tipe pena yang ditujukan bagi mereka yang paling bergantung pada oksigen: petambak ikan dan udang. Meter ini membaca oksigen dua cara dari sampel yang sama — 0.00–20.00 mg/L dan 0.0–200.0 % saturasi — pada resolusi 0,01 mg/L / 0,1 %, dengan akurasi ±2 % F.S.

Elektroda galvanik DO yang dapat diganti tidak memerlukan waktu tunggu polarisasi dan tanpa penggantian membran rutin dari sisi pengguna; kalibrasi adalah prosedur 1 atau 2 titik terhadap larutan bebas oksigen atau udara jenuh. Pena 90 g berperingkat IP67 dan berjalan dengan satu baterai AAA.

Aplikasi

Catatan pemilihan

  1. Baca kedua satuan: mg/L memberi tahu kandungan oksigen aktual untuk keputusan penebaran, sedangkan % saturasi menunjukkan seberapa dekat air dengan maksimumnya pada suhu dan salinitas saat ini.
  2. Kalibrasi sebelum batch kritis: kalibrasi 1 titik pada udara jenuh cukup untuk sebagian besar pekerjaan kolam; gunakan prosedur 2 titik (0 % plus 100 %) saat Anda membutuhkan seluruh rentang akurat.
  3. Simpan elektroda galvanik dengan tutup pelindung terpasang dan jaga ujung sensor tetap basah — ujung kering adalah penyebab paling umum respons lambat.

Pertanyaan umum

Apa bedanya mg/L dengan % saturasi?

mg/L adalah berat oksigen dalam setiap liter air; % saturasi membandingkan nilai itu dengan maksimum teoretis pada suhu, tekanan dan salinitas saat ini. Kedua sudut pandang berasal dari pengukuran yang sama.

Apakah elektrodanya dapat diganti dan perlu membran?

DO100 menggunakan elektroda galvanik yang dapat diganti, dirancang agar penggantian membran rutin bukan bagian dari pemakaian normal — elektroda itu sendiri adalah bagian yang ditukar saat mencapai akhir masa pakai.

Apa arti dua titik kalibrasi itu?

Prosedur 1 titik mengkalibrasi terhadap oksigen jenuh 100 % (udara lembap); titik kedua opsional menggunakan larutan bebas oksigen 0 %. Lebih banyak titik meningkatkan akurasi di seluruh rentang tetapi tidak wajib untuk setiap pemeriksaan kolam.

Mengapa DO penting sebelum penebaran atau pemberian pakan?

Oksigen terlarut rendah membuat ikan dan udang stres, memperlambat pertumbuhan, dan dapat menyebabkan kematian pada malam hari. Pembacaan pena cepat memungkinkan Anda memastikan kadar cukup dan mengatur waktu aerasi sebelum bertindak.

Tổng quan

DO100 là máy đo oxy hòa tan dạng bút hướng đến những người phụ thuộc nhiều nhất vào oxy: người nuôi cá và tôm. Máy đọc oxy theo hai cách từ cùng một mẫu — 0.00–20.00 mg/L và 0.0–200.0 % bão hòa — với độ phân giải 0,01 mg/L / 0,1 % và sai số ±2 % F.S.

Điện cực oxy dạng galvanic có thể thay thế không cần chờ phân cực và không cần thay màng định kỳ từ phía người dùng; hiệu chuẩn là quy trình 1 hoặc 2 điểm với dung dịch không oxy hoặc không khí bão hòa. Cây bút 90 g đạt IP67 và chạy bằng một pin AAA.

Ứng dụng

Lưu ý chọn mua

  1. Đọc cả hai đơn vị: mg/L cho biết hàm lượng oxy thực tế để quyết định thả giống, còn % bão hòa cho biết nước đang ở mức bao xa so với mức tối đa ở nhiệt độ và độ mặn hiện tại.
  2. Hiệu chuẩn trước các mẻ quan trọng: hiệu chuẩn 1 điểm bằng không khí bão hòa đủ cho hầu hết công việc ao; dùng quy trình 2 điểm (0 % cộng 100 %) khi cần toàn dải thật chính xác.
  3. Bảo quản điện cực galvanic với nắp bảo vệ và giữ đầu cảm biến ẩm — đầu bị khô là nguyên nhân phổ biến nhất gây phản hồi chậm.

Câu hỏi thường gặp

Khác nhau giữa mg/L và % bão hòa là gì?

mg/L là trọng lượng oxy trong mỗi lít nước; % bão hòa so sánh giá trị đó với mức tối đa lý thuyết ở nhiệt độ, áp suất và độ mặn hiện tại. Hai góc nhìn đến từ cùng một phép đo.

Điện cực có thay được không và có cần màng không?

DO100 dùng điện cực galvanic thay thế được, thiết kế sao cho việc thay màng định kỳ không nằm trong sử dụng bình thường — bản thân điện cực là bộ phận được thay khi hết hạn dùng.

Hai điểm hiệu chuẩn nghĩa là gì?

Quy trình 1 điểm hiệu chuẩn theo oxy bão hòa 100 % (không khí ẩm); điểm thứ hai tùy chọn dùng dung dịch không oxy 0 %. Nhiều điểm hơn cải thiện độ chính xác toàn dải nhưng không bắt buộc cho mỗi lần kiểm tra ao.

Vì sao DO quan trọng trước khi thả giống hoặc cho ăn?

Oxy hòa tan thấp làm cá tôm stress, chậm lớn và có thể gây chết vào ban đêm. Một lần đọc nhanh bằng bút giúp bạn xác nhận mức đủ và canh thời điểm sục khí trước khi hành động.

ภาพรวม

DO100 คือเครื่องวัดออกซิเจนละลายน้ำแบบปากกาที่ออกแบบสำหรับผู้ที่พึ่งพาออกซิเจนมากที่สุด: ผู้เลี้ยงปลาและกุ้ง เครื่องอ่านออกซิเจนสองแบบจากตัวอย่างเดียวกัน — 0.00–20.00 มก./ล. และ 0.0–200.0 % ความอิ่มตัว — ความละเอียด 0.01 มก./ล. / 0.1 % ความแม่น ±2 % F.S.

อิเล็กโทรดออกซิเจนแบบกัลวานิกที่เปลี่ยนได้ไม่ต้องรอโพลาไรซ์และไม่ต้องเปลี่ยนเมมเบรนเป็นประจำจากฝั่งผู้ใช้ การเทียบมาตรฐานเป็นขั้นตอน 1 หรือ 2 จุดกับสารละลายไร้ออกซิเจนหรืออากาศอิ่มตัว ตัวปากกา 90 กรัมระดับ IP67 ใช้แบตเตอรี่ AAA ก้อนเดียว

การใช้งาน

ข้อควรพิจารณาในการเลือก

  1. อ่านทั้งสองหน่วย: มก./ล. บอกปริมาณออกซิเจนจริงสำหรับการตัดสินใจปล่อยพันธุ์ ส่วน % ความอิ่มตัวบอกว่าน้ำใกล้ค่าสูงสุดตามอุณหภูมิและความเค็มปัจจุบันแค่ไหน
  2. เทียบมาตรฐานก่อนรอบสำคัญ: การเทียบ 1 จุดกับอากาศอิ่มตัวเพียงพอสำหรับงานบ่อส่วนใหญ่ ใช้ขั้นตอน 2 จุด (0 % บวก 100 %) เมื่อต้องการความแม่นทั่วทั้งช่วง
  3. เก็บอิเล็กโทรดกัลวานิกโดยใส่ฝาครอบป้องกันและรักษาปลายเซนเซอร์ให้ชื้น — ปลายแห้งคือสาเหตุที่พบบ่อยที่สุดของการตอบสนองช้า

คำถามที่พบบ่อย

มก./ล. กับ % ความอิ่มตัวต่างกันอย่างไร?

มก./ล. คือน้ำหนักออกซิเจนในน้ำแต่ละลิตร ส่วน % ความอิ่มตัวเปรียบเทียบค่านั้นกับค่าสูงสุดทางทฤษฎีที่อุณหภูมิ ความดัน และความเค็มปัจจุบัน มุมมองทั้งสองมาจากการวัดเดียวกัน

อิเล็กโทรดเปลี่ยนได้ไหมและต้องใช้เมมเบรนหรือไม่?

DO100 ใช้อิเล็กโทรดกัลวานิกที่เปลี่ยนได้ ออกแบบให้การเปลี่ยนเมมเบรนเป็นประจำไม่ใช่ส่วนหนึ่งของการใช้งานปกติ — ตัวอิเล็กโทรดเองคือชิ้นส่วนที่เปลี่ยนเมื่อหมดอายุใช้งาน

จุดเทียบมาตรฐานสองจุดหมายถึงอะไร?

ขั้นตอน 1 จุดเทียบกับออกซิเจนอิ่มตัว 100 % (อากาศชื้น) จุดที่สองแบบเลือกได้ใช้สารละลายไร้ออกซิเจน 0 % ยิ่งหลายจุดยิ่งแม่นทั่วช่วง แต่ไม่จำเป็นทุกครั้งที่ตรวจบ่อ

ทำไม DO ถึงสำคัญก่อนปล่อยพันธุ์หรือให้อาหาร?

ออกซิเจนละลายต่ำทำให้ปลาและกุ้งเครียด โตช้า และอาจตายได้ในเวลากลางคืน การอ่านเร็วด้วยปากกาช่วยให้คุณยืนยันระดับเพียงพอและจัดจังหวะเติมอากาศก่อนลงมือ

Gambaran keseluruhan

DO100 ialah meter oksigen terlarut jenis pen yang ditujukan kepada mereka yang paling bergantung pada oksigen: penternak ikan dan udang. Ia membaca oksigen dua cara daripada sampel yang sama — 0.00–20.00 mg/L dan 0.0–200.0 % ketepuan — pada resolusi 0.01 mg/L / 0.1 %, dengan ketepatan ±2 % F.S.

Elektrod galvanik DO yang boleh diganti tidak memerlukan waktu menunggu polarisasi dan tiada penukaran membran rutin daripada pihak pengguna; penentukuran ialah prosedur 1 atau 2 titik terhadap larutan bebas oksigen atau udara tepu. Pen 90 g berkelas IP67 dan berjalan dengan satu bateri AAA.

Aplikasi

Nota pemilihan

  1. Baca kedua-dua unit: mg/L memberitahu kandungan oksigen sebenar untuk keputusan penebaran, manakala % ketepuan menunjukkan sejauh mana air hampir dengan maksimumnya pada suhu dan kemasinan semasa.
  2. Kalibrasi sebelum kelompok kritikal: kalibrasi 1 titik pada udara tepu memadai untuk kebanyakan kerja kolam; gunakan prosedur 2 titik (0 % tambah 100 %) apabila anda memerlukan keseluruhan julat tepat.
  3. Simpan elektrod galvanik dengan penutup pelindung terpasang dan pastikan hujung penderia lembap — hujung kering ialah punca paling lazim respons perlahan.

Soalan lazim

Apakah perbezaan mg/L dengan % ketepuan?

mg/L ialah berat oksigen dalam setiap liter air; % ketepuan membandingkan nilai itu dengan maksimum teori pada suhu, tekanan dan kemasinan semasa. Kedua-dua sudut pandang datang daripada ukuran yang sama.

Bolehkah elektrod diganti dan adakah ia memerlukan membran?

DO100 menggunakan elektrod galvanik yang boleh diganti, direka supaya penukaran membran rutin bukan sebahagian penggunaan biasa — elektrod itu sendiri ialah bahagian yang ditukar apabila mencapai akhir hayat.

Apakah maksud dua titik penentukuran itu?

Prosedur 1 titik menentukur terhadap oksigen tepu 100 % (udara lembap); titik kedua pilihan menggunakan larutan bebas oksigen 0 %. Lebih banyak titik meningkatkan ketepatan seluruh julat tetapi tidak wajib untuk setiap pemeriksaan kolam.

Mengapa DO penting sebelum penebaran atau pemberian makanan?

Oksigen terlarut rendah menyebabkan ikan dan udang stres, melambatkan pertumbuhan dan boleh menyebabkan kematian pada waktu malam. Bacaan pen pantas membolehkan anda mengesahkan paras mencukupi dan mengatur masa pengudaraan sebelum bertindak.

Pangkalahatang-ideya

Ang DO100 ay isang panulat na dissolved oxygen meter na nakatuon sa mga taong higit na umaasa sa oxygen: mga magsasaka ng isda at hipon. Binabasa nito ang oxygen sa dalawang paraan mula sa parehong sampol — 0.00–20.00 mg/L at 0.0–200.0 % saturation — sa resolusyong 0.01 mg/L / 0.1 %, na may katumpakang ±2 % F.S.

Ang mapapalitang galvanic DO electrode ay hindi nangangailangan ng paghihintay sa polarization at walang routine membrane exchange mula sa panig ng gumagamit; ang pagkakalibrate ay 1- o 2-puntong pamamaraan laban sa oxygen-free solution o saturated air. Ang 90 g na panulat ay may rating na IP67 at tumatakbo sa isang bateryang AAA.

Mga aplikasyon

Mga paalala sa pagpili

  1. Basahin ang parehong unit: sinasabi ng mg/L ang aktwal na nilalaman ng oxygen para sa mga desisyon sa paglalabas ng alalayan, habang ang % saturation ay nagpapakita kung gaano kalapit ang tubig sa maximum nito sa kasalukuyang temperatura at kaalatan.
  2. Mag-kalibrate bago ang mga kritikal na batch: ang 1-puntong pagkakalibrate sa saturated air ay sapat para sa karamihan ng gawaing pond; gamitin ang 2-puntong pamamaraan (0 % plus 100 %) kapag kailangan mong maging tumpak ang buong range.
  3. Itago ang galvanic electrode na naka-install ang protective cap at panatilihing basa ang sensing tip — ang natuyong tip ang pinakakaraniwang sanhi ng mabagal na tugon.

Mga madalas itanong

Ano ang pagkakaiba ng mg/L at % saturation?

Ang mg/L ay ang timbang ng oxygen sa bawat litro ng tubig; inihahambing ng % saturation ang halagang iyon sa teoretikal na maximum sa kasalukuyang temperatura, presyon at kaalatan. Parehong pananaw ang nagmumula sa iisang pagsukat.

Mapapalitan ba ang electrode at kailangan ba nito ng membrane?

Gumagamit ang DO100 ng mapapalitang galvanic electrode na dinisenyo upang ang routine membrane exchange ay hindi bahagi ng normal na paggamit — ang electrode mismo ang bahaging pinapalitan kapag umabot na ito sa katapusan ng buhay nito.

Ano ang ibig sabihin ng dalawang calibration point?

Ang 1-puntong pamamaraan ay nagkakalibrate laban sa 100 % saturated oxygen (basa-basang hangin); ang opsyonal na ikalawang punto ay gumagamit ng 0 % oxygen-free solution. Mas maraming punto ang nagpapahusay ng katumpakan sa buong range ngunit hindi kinakailangan sa bawat pond check.

Bakit mahalaga ang DO bago maglabas ng alalayan o magpakain?

Ang mababang dissolved oxygen ay nagpapastress sa isda at hipon, nagpapabagal ng paglaki, at maaaring magdulot ng pagkamatay sa gabi. Ang mabilis na pagbasa gamit ang panulat ay nagbibigay-daan upang kumpirmahin ang sapat na antas at mag-ayos ng aeration timing bago kumilos.

Transparent Sourcing, Every Order

This product is sourced factory-direct from a certified Chinese manufacturer. You pay the factory price — no markup. Our income comes from the export tax rebate, not from your bill.

Request a Quote