| Measurement Range | DO: 0~25.00 mg/L; Temperature: 0~60℃ |
|---|---|
| Measurement Error | DO: ±1% F.S.; Temperature: ±0.3℃ |
| Automatic Temperature Compensation | 0~60℃ |
| Electrode Residual Signal | < 1‰ |
| Response Time (90% final value) | < 60s at 25°C; < 30s at 35°C |
| Stability | Drift < 2% F.S. per week at constant pressure and temperature |
| Signal Output | 0~20 mA, 4~20 mA, 20~4 mA (load resistance < 750 Ω) |
| 3 Relay Control Contacts | 3A 240 VAC, 3A 28 VDC or 120 VAC |
| Power Supply (optional) | 85~264 VAC±10%, power ≤3W; 9~36 VDC, power ≤3W |
| External Dimensions | 144×144×118mm |
| Installation Method | Wall-mounted / panel mount (embedded) |
| Panel Cutout | 138×138mm |
| Working Environment | Ambient temp -10~60°C; relative humidity ≤90%; no strong magnetic field interference (except earth magnetic field) |
| Applications | Water treatment, environmental monitoring, laboratories, food & beverage, aquaculture |
| Certifications | Manufactured under ISO 9001 QMS · CE/RoHS/FDA compliance varies by model (certificates available upon request) |
Ang DO6000M ay isang panel dissolved oxygen monitor na binuo sa paligid ng isang membrane-covered amperometric electrode, ang teknolohiyang alam na ng karamihan sa mga wastewater plant kung paano patakbuhin. Sumusukat ito ng 0 hanggang 25.00 mg/L dissolved oxygen na may basic error na ±1% ng full scale, nag-uulat ng temperatura na may katumpakan na ±0.3 °C, at may automatic temperature compensation sa buong 0–60 °C range. Ang 144 × 144 × 118 mm na housing ay nagbibigay ng isang analog output at tatlong relay output para sa direktang koneksyon sa PLC o starter panel.
Ang bilis ng pagtugon at katatagan ang mga lakas nito sa operasyon: naaabot ng electrode ang 90% ng final value sa loob ng wala pang 60 segundo sa 25 °C at wala pang 30 segundo sa 35 °C, at nananatiling mas mababa sa 2% ng full scale bawat linggo ang drift sa pare-parehong pressure at temperatura. Ang metro ay tumatakbo sa 85–264 VAC o 9–36 VDC na hindi lalampas sa 3 W, kaya madali itong i-retrofit sa mga planta na may kuryente at sa mga malalayong istasyon na solar- o battery-powered.
Ano ang kahulugan ng electrode-based para sa isang DO monitor?
Nangangahulugan ito na ang sensing element ay isang membrane-covered amperometric electrode na kumukonsumo ng oxygen na tumatawid sa membrane at lumilikha ng current na proporsyonal sa dissolved oxygen. Ang membrane at electrolyte ay consumable na may limitadong working life, at ito ang pangunahing operating cost ng teknolohiyang ito.
Ano ang range at accuracy ng DO6000M?
Dissolved oxygen mula 0 hanggang 25.00 mg/L na may basic error na ±1% ng full scale, kasama ang temperatura mula 0 hanggang 60 °C na may katumpakan na ±0.3 °C. Ang automatic temperature compensation ay built-in sa buong temperature range.
Gaano kabilis itong tumugon?
Naaabot ng electrode ang 90% ng final value sa loob ng wala pang 60 segundo sa 25 °C at wala pang 30 segundo sa 35 °C, sapat na mabilis para sa aeration control na inaayos ang blower output ayon sa nagbabagong oxygen demand.
Paano pinapagana ang instrumento?
Sa pamamagitan ng 85–264 VAC o 9–36 VDC, na kumukonsumo ng hindi hihigit sa 3 W sa pareho. Ang universal AC/DC input ang dahilan kung bakit gumagana ang parehong unit sa grid-powered plant at sa DC-only remote station.
Anong mga output ang ibinibigay nito para sa mga control system?
Isang analog output na maaaring piliin bilang 0–20, 4–20, o 20–4 mA (load na mas mababa sa 750 Ω) at tatlong relay contact na may rating na 3 A sa 240 VAC para sa mga alarm, blower staging, o valve control.