PH100P Puncture-style pH tester for solid and semi-solid samples. Specialized for soil

Puncture-style pH tester for solid and semi-solid samples. Specialized for soil, fruit, vegetable, and meat internal pH measurement.
✓ Transparent sourcing — factory-direct price, no markup
Request a Quote WhatsApp Us

Product Specifications

ModelPH100P
Measurement Range0.00~13.00pH
Resolution0.01pH
Accuracy±0.03pH
CalibrationAuto-recognize 3-point calibration solution
ElectrodeReplaceable stainless steel piercing pH electrode
Electrode Dimensions105mm×φ14mm
Temperature Measuring Range0~100.0 ℃/ 32~212 ℉
Operating Temperature Range0~60.0 ℃/ 32~140 ℉
Display20×30mm multi-line LCD display
Temperature CompensationATC automatic / MTC manual
Protection RatingIP67
Power Supply1 × AAA battery
Auto Backlight1 minute
Auto Power Off10 minutes
Dimensions250×40×45mm
Weight140g
ApplicationsWater treatment, environmental monitoring, laboratories, food & beverage, aquaculture
CertificationsManufactured under ISO 9001 QMS · CE/RoHS/FDA compliance varies by model (certificates available upon request)

Overview

The PH100P is a puncture-style pH tester built for solid and semi-solid samples. A replaceable stainless-steel piercing electrode (105 mm × φ14 mm) is pushed directly into the material, so the pH of soil, fruit, vegetables and meat is read inside the sample instead of from a surface wash.

The 250 mm pen measures 0.00–13.00 pH at 0.01 resolution with ±0.03 pH accuracy, auto-recognizes a 3-point calibration, and is rated IP67. The sharp probe is the replaceable part — when the tip wears, a new piercing electrode restores full performance.

Applications

Selection notes

  1. Choose the right penetration depth: the measuring zone sits at the stainless tip, so push the probe far enough for the tip to be fully embedded in the sample.
  2. Rinse and dry the probe between different samples — cross-contamination between soil batches changes readings noticeably.
  3. Operating temperature is 0–60 °C. For frozen or very hot materials, let the sample return to room temperature before measuring.

Frequently asked questions

Why is the range 0.00–13.00 instead of 0.00–14.00?

The PH100P is optimized for soil, produce and meat matrices rather than strong alkaline liquids, and its specification is stated as 0.00–13.00 pH at ±0.03 accuracy. For 0–14 liquid work, the flat-electrode PH100 is the matching pen.

Can the piercing probe be replaced?

Yes. The stainless-steel piercing electrode is a replaceable part (105 mm × φ14 mm). A worn or damaged tip is swapped out without replacing the whole meter.

Do I need to prepare the sample before measuring?

For soil, moisten dry soil slightly and let it settle before inserting the probe. For produce and meat, measure directly in the flesh; rinse the tip between samples.

How does the PH100P differ from the PH100?

The PH100P reads the interior of solid and semi-solid samples through a piercing steel electrode. The PH100 reads liquids and surfaces with a flat electrode over 0.00–14.00 pH at ±0.01.

概述

PH100P 是一款面向固体与半固体样品的穿刺式 pH 测试仪。可更换的不锈钢穿刺电极(105 mm × φ14 mm)直接插入被测物内部,因此土壤、水果、蔬菜和肉类的 pH 是在样品内部读取,而非表面冲洗液。

全长 250 mm 的笔身测量范围 0.00–13.00 pH,分辨率 0.01,精度 ±0.03 pH,自动识别三点校准,防护等级 IP67。尖锐探针是可更换部件——尖端磨损后换一支新穿刺电极即可恢复全部性能。

应用场景

选型建议

  1. 注意插入深度:测量区位于不锈钢尖端,探针需插入足够深,使尖端完全没入样品。
  2. 不同样品之间冲洗并擦干探针——土壤批次间的交叉污染会明显影响读数。
  3. 工作温度 0–60 °C。冷冻或过热的物料应先回到室温再测量。

常见问题

为什么量程是 0.00–13.00 而不是 0.00–14.00?

PH100P 面向土壤、农产品和肉类等基质,而非强碱性液体,其标称规格为 0.00–13.00 pH、精度 ±0.03。需要 0–14 的液体测量时,平面电极 PH100 是对应的笔式选择。

穿刺探针可以更换吗?

可以。不锈钢穿刺电极是可更换部件(105 mm × φ14 mm),尖端磨损或损坏时只需更换电极,无需更换整机。

测量前需要处理样品吗?

测土壤时,可先让偏干的土壤略湿润并静置再插入探针;测农产品和肉类时直接插入果肉/肉质内部,样品之间冲洗尖端即可。

PH100P 与 PH100 有何区别?

PH100P 通过穿刺式钢电极读取固体与半固体样品内部;PH100 用平面电极测量液体和表面,量程 0.00–14.00 pH、精度 ±0.01。

Ikhtisar

PH100P adalah penguji pH tipe tusuk yang dibuat untuk sampel padat dan semi-padat. Elektroda penusuk baja tahan karat yang dapat diganti (105 mm × φ14 mm) didorong langsung ke dalam bahan, sehingga pH tanah, buah, sayuran dan daging dibaca di dalam sampel, bukan dari cucian permukaan.

Pena sepanjang 250 mm ini mengukur 0.00–13.00 pH dengan resolusi 0,01 dan akurasi ±0,03 pH, mengenali kalibrasi 3 titik secara otomatis, dan berperingkat IP67. Probe tajam adalah bagian yang dapat diganti — saat ujung aus, elektroda penusuk baru memulihkan kinerja penuh.

Aplikasi

Catatan pemilihan

  1. Pilih kedalaman tusukan yang tepat: zona pengukuran berada di ujung baja, jadi dorong probe cukup dalam agar ujungnya tertanam penuh di dalam sampel.
  2. Bilas dan keringkan probe di antara sampel yang berbeda — kontaminasi silang antarbatch tanah mengubah pembacaan secara nyata.
  3. Suhu operasi 0–60 °C. Untuk bahan beku atau sangat panas, biarkan sampel kembali ke suhu ruang sebelum mengukur.

Pertanyaan umum

Mengapa rentangnya 0.00–13.00, bukan 0.00–14.00?

PH100P dioptimalkan untuk matriks tanah, hasil bumi dan daging, bukan cairan basa kuat, dan spesifikasinya dinyatakan 0.00–13.00 pH pada akurasi ±0,03. Untuk kerja cairan 0–14, PH100 ber-elektroda datar adalah pena yang sesuai.

Bisakah probe penusuk diganti?

Ya. Elektroda penusuk baja tahan karat adalah komponen yang dapat diganti (105 mm × φ14 mm). Ujung yang aus atau rusak ditukar tanpa mengganti seluruh meter.

Apakah sampel perlu disiapkan sebelum diukur?

Untuk tanah, basahi sedikit tanah kering dan biarkan mengendap sebelum memasukkan probe. Untuk hasil bumi dan daging, ukur langsung di dalam daging buah/daging; bilas ujung di antara sampel.

Apa bedanya PH100P dengan PH100?

PH100P membaca bagian dalam sampel padat dan semi-padat melalui elektroda baja penusuk. PH100 membaca cairan dan permukaan dengan elektroda datar pada 0.00–14.00 pH, akurasi ±0,01.

Tổng quan

PH100P là máy đo pH dạng chọc dành cho mẫu rắn và bán rắn. Điện cực chọc bằng thép không gỉ có thể thay thế (105 mm × φ14 mm) được đâm thẳng vào vật liệu, vì vậy pH của đất, trái cây, rau củ và thịt được đọc bên trong mẫu thay vì từ nước rửa bề mặt.

Cây bút dài 250 mm đo 0.00–13.00 pH, độ phân giải 0,01 và sai số ±0,03 pH, tự nhận diện hiệu chuẩn 3 điểm và đạt IP67. Đầu dò nhọn là bộ phận thay thế được — khi đầu mòn, điện cực chọc mới sẽ khôi phục toàn bộ hiệu năng.

Ứng dụng

Lưu ý chọn mua

  1. Chọn độ sâu chọc phù hợp: vùng đo nằm ở đầu nhọn bằng thép, vì vậy hãy đẩy đầu dò đủ sâu để đầu nhọn chìm hoàn toàn trong mẫu.
  2. Rửa và lau khô đầu dò giữa các mẫu khác nhau — nhiễm chéo giữa các mẻ đất làm thay đổi chỉ số rõ rệt.
  3. Nhiệt độ vận hành 0–60 °C. Với vật liệu đông lạnh hoặc rất nóng, hãy để mẫu về nhiệt độ phòng trước khi đo.

Câu hỏi thường gặp

Vì sao dải đo là 0.00–13.00 thay vì 0.00–14.00?

PH100P tối ưu cho nền mẫu đất, nông sản và thịt hơn là dung dịch kiềm mạnh, và thông số công bố là 0.00–13.00 pH ở sai số ±0,03. Với công việc đo chất lỏng 0–14, PH100 điện cực phẳng là cây bút phù hợp.

Đầu dò chọc có thay được không?

Có. Điện cực chọc bằng thép không gỉ là bộ phận thay thế được (105 mm × φ14 mm). Đầu bị mòn hoặc hỏng sẽ được thay mà không cần thay toàn bộ máy.

Có cần chuẩn bị mẫu trước khi đo không?

Với đất, hãy làm ẩm nhẹ đất khô và để lắng trước khi cắm đầu dò. Với nông sản và thịt, đo trực tiếp bên trong thịt quả/thịt; rửa đầu dò giữa các mẫu.

PH100P khác PH100 ở điểm nào?

PH100P đọc bên trong mẫu rắn và bán rắn bằng điện cực thép chọc. PH100 đọc chất lỏng và bề mặt bằng điện cực phẳng ở dải 0.00–14.00 pH, sai số ±0,01.

ภาพรวม

PH100P คือเครื่องวัด pH แบบแทงสำหรับตัวอย่างของแข็งและกึ่งของแข็ง อิเล็กโทรดแทงสแตนเลสที่เปลี่ยนได้ (105 มม. × φ14 มม.) ถูกกดตรงเข้าไปในวัสดุ จึงอ่านค่า pH ของดิน ผลไม้ ผัก และเนื้อสัตว์จากภายในตัวอย่างแทนที่จะอ่านจากน้ำล้างพื้นผิว

ตัวเครื่องยาว 250 มม. วัดช่วง 0.00–13.00 pH ความละเอียด 0.01 ความแม่น ±0.03 pH จดจำการเทียบมาตรฐาน 3 จุดอัตโนมัติ และระดับการป้องกัน IP67 หัววัดแหลมเป็นชิ้นส่วนที่เปลี่ยนได้ — เมื่อปลายสึก เปลี่ยนอิเล็กโทรดแทงใหม่ก็คืนประสิทธิภาพเต็มรูปแบบ

การใช้งาน

ข้อควรพิจารณาในการเลือก

  1. เลือกความลึกการแทงที่เหมาะสม: โซนวัดอยู่ที่ปลายสแตนเลส ดังนั้นต้องกดหัววัดให้ลึกพอที่ปลายจะฝังเต็มในตัวอย่าง
  2. ล้างและเช็ดหัววัดให้แห้งระหว่างตัวอย่างที่ต่างกัน — การปนเปื้อนข้ามชุดดินทำให้ค่าอ่านเปลี่ยนอย่างเห็นได้ชัด
  3. อุณหภูมิการทำงาน 0–60 °C สำหรับวัสดุแช่แข็งหรือร้อนจัด ให้ตัวอย่างกลับสู่อุณหภูมิห้องก่อนวัด

คำถามที่พบบ่อย

ทำไมช่วงวัดเป็น 0.00–13.00 ไม่ใช่ 0.00–14.00?

PH100P ถูกออกแบบให้เหมาะกับเนื้อดิน ผลผลิตเกษตร และเนื้อสัตว์ มากกว่าของเหลวที่เป็นด่างเข้ม และสเปกที่ประกาศคือ 0.00–13.00 pH ที่ความแม่น ±0.03 สำหรับงานวัดของเหลว 0–14 PH100 แบบอิเล็กโทรดแบนคือปากกาที่ตรงโจทย์

หัววัดแบบแทงเปลี่ยนได้หรือไม่?

ได้ อิเล็กโทรดแทงสแตนเลสเป็นชิ้นส่วนที่เปลี่ยนได้ (105 มม. × φ14 มม.) ปลายที่สึกหรือเสียหายจะถูกเปลี่ยนโดยไม่ต้องเปลี่ยนทั้งเครื่อง

ต้องเตรียมตัวอย่างก่อนวัดหรือไม่?

สำหรับดิน ให้ดินแห้งชุ่มน้ำเล็กน้อยและปล่อยให้ตกตะกอนก่อนเสียบหัววัด สำหรับผลผลิตเกษตรและเนื้อสัตว์ วัดโดยตรงในเนื้อ ผลไม้/เนื้อสัตว์ ล้างปลายระหว่างตัวอย่าง

PH100P ต่างจาก PH100 อย่างไร?

PH100P อ่านภายในตัวอย่างของแข็งและกึ่งของแข็งผ่านอิเล็กโทรดเหล็กแทง ส่วน PH100 อ่านของเหลวและพื้นผิวด้วยอิเล็กโทรดแบนที่ช่วง 0.00–14.00 pH ความแม่น ±0.01

Gambaran keseluruhan

PH100P ialah penguji pH jenis cucuk yang dibina untuk sampel pepejal dan separa pepejal. Elektrod pencucuk keluli tahan karat yang boleh diganti (105 mm × φ14 mm) ditolak terus ke dalam bahan, maka pH tanah, buah, sayuran dan daging dibaca di dalam sampel dan bukannya daripada cucian permukaan.

Pen sepanjang 250 mm ini mengukur 0.00–13.00 pH pada resolusi 0.01 dengan ketepatan ±0.03 pH, mengecam penentukuran 3 titik secara automatik, dan berkelas IP67. Prob tajam ialah bahagian yang boleh diganti — apabila hujung haus, elektrod pencucuk baharu memulihkan prestasi penuh.

Aplikasi

Nota pemilihan

  1. Pilih kedalaman cucukan yang betul: zon pengukuran berada di hujung keluli, jadi tolak prob cukup dalam supaya hujungnya tertanam sepenuhnya dalam sampel.
  2. Bilas dan keringkan prob antara sampel yang berbeza — pencemaran silang antara kelompok tanah mengubah bacaan dengan ketara.
  3. Suhu operasi 0–60 °C. Untuk bahan beku atau sangat panas, biarkan sampel kembali ke suhu bilik sebelum mengukur.

Soalan lazim

Mengapa julatnya 0.00–13.00 dan bukannya 0.00–14.00?

PH100P dioptimumkan untuk matriks tanah, hasil tani dan daging berbanding cecair beralkali kuat, dan spesifikasinya dinyatakan sebagai 0.00–13.00 pH pada ketepatan ±0.03. Untuk kerja cecair 0–14, PH100 ber-elektrod rata ialah pen yang sepadan.

Bolehkah prob pencucuk diganti?

Ya. Elektrod pencucuk keluli tahan karat ialah bahagian yang boleh diganti (105 mm × φ14 mm). Hujung yang haus atau rosak ditukar tanpa mengganti keseluruhan meter.

Adakah sampel perlu disediakan sebelum mengukur?

Untuk tanah, lembapkan sedikit tanah kering dan biarkan ia mendap sebelum memasukkan prob. Untuk hasil tani dan daging, ukur terus di dalam isi buah/daging; bilas hujung antara sampel.

Apakah perbezaan PH100P dengan PH100?

PH100P membaca bahagian dalam sampel pepejal dan separa pepejal melalui elektrod keluli pencucuk. PH100 membaca cecair dan permukaan dengan elektrod rata pada 0.00–14.00 pH, ketepatan ±0.01.

Pangkalahatang-ideya

Ang PH100P ay isang puncture-style pH tester na ginawa para sa solid at semi-solid na mga sampol. Ang mapapalitang stainless-steel piercing electrode (105 mm × φ14 mm) ay direktang itinutulak sa materyal, kaya't ang pH ng lupa, prutas, gulay at karne ay binabasa sa loob ng sampol imbes na mula sa panghugas sa ibabaw.

Ang 250 mm na panulat ay sumusukat ng 0.00–13.00 pH sa resolusyong 0.01 na may katumpakang ±0.03 pH, awtomatikong kinikilala ang 3-puntong pagkakalibrate, at may rating na IP67. Ang matulis na probe ay ang mapapalitang bahagi — kapag napudpod ang dulo, isang bagong piercing electrode ang nagpapanumbalik ng buong pagganap.

Mga aplikasyon

Mga paalala sa pagpili

  1. Piliin ang tamang lalim ng pagtusok: nasa dulo ng stainless tip ang measuring zone, kaya itulak nang sapat ang probe para tuluyang mailubog ang dulo sa sampol.
  2. Banlawan at patuyuin ang probe sa pagitan ng iba't ibang sampol — ang cross-contamination sa pagitan ng mga batch ng lupa ay kapansin-pansing nagbabago ng pagbasa.
  3. Ang operating temperature ay 0–60 °C. Para sa frozen o sobrang init na materyales, hayaang bumalik sa temperatura ng kuwarto ang sampol bago sukatin.

Mga madalas itanong

Bakit 0.00–13.00 ang range imbes na 0.00–14.00?

Ang PH100P ay inoptimisa para sa lupa, ani at karne na matrices imbes na malalakas na alkaline liquid, at ang spec nito ay 0.00–13.00 pH sa katumpakang ±0.03. Para sa 0–14 na likidong trabaho, ang PH100 na may flat electrode ang katapat na panulat.

Mapapalitan ba ang piercing probe?

Oo. Ang stainless-steel piercing electrode ay isang mapapalitang bahagi (105 mm × φ14 mm). Ang pudpod o sirang dulo ay pinapalitan nang hindi pinapalitan ang buong metro.

Kailangan bang ihanda ang sampol bago sukatin?

Para sa lupa, basain nang bahagya ang tuyong lupa at hayaang tumira bago isingit ang probe. Para sa mga ani at karne, sukatin nang direkta sa laman; banlawan ang dulo sa pagitan ng mga sampol.

Ano ang pagkakaiba ng PH100P sa PH100?

Binabasa ng PH100P ang loob ng solid at semi-solid na sampol sa pamamagitan ng piercing steel electrode. Binabasa ng PH100 ang mga likido at mga ibabaw gamit ang flat electrode sa 0.00–14.00 pH, katumpakang ±0.01.

Transparent Sourcing, Every Order

This product is sourced factory-direct from a certified Chinese manufacturer. You pay the factory price — no markup. Our income comes from the export tax rebate, not from your bill.

Request a Quote