01 Electromagnetic flowmeter
8 product models · Keywords: 01 Electromagnetic flowmeter · SE10A · SE11E · SE11H
SE10A — The power supply of SE10A can only be 24V DC and cannot be connected to 220V AC; there are few options for electrodes and linings, and it is not suita | Application: If your working condition has a diameter of 10-300mm, only a 24V power supply, the medium is a conve
SE11E — If the budget allows, the working conditions are complex, or there are high requirements for accuracy/reliability, SE11E is the "one-stop" choice. | Application: It covers almost all conductive liquid measurement needs from 3mm small tubes to 2m large tubes, fro
SE11H — SE11H = All the high performance of SE11E + Mixed excitation specifically for slurry reinforcement + Wear resistant liners/electrodes | Application: If you are measuring solid-containing fluids such as coal-water slurry, ore slurry, paper pulp, mud,
View all 8 01 Electromagnetic flowmeter products →
02 Electromagnetic water meter
1 product model · Keywords: 02 Electromagnetic water meter · Electromagnetic water meter
Electromagnetic water meter — Need precision, pressure, and small diameter → SEB600S/SEB600
The pipe diameter needs to be large, the water supply needs to be installed continuously | Application: Scenario Recommended product Reason
Main city water supply pipeline (DN500) SEB600 high precision, n
View all 1 02 Electromagnetic water meter products →
03 Vortex flowmeter
3 product models · Keywords: 03 Vortex flowmeter · SV21 series · SV23 sanitary vortex flowmeter · SVH digital vortex street
SV21 series — SV21 adopts a hexagonal vortex generator and digital dynamic filtering, which is anti-vibration and has zero drift. It also supports Bluetooth APP deb | Application: It is suitable for steam, gas and liquid flow measurement. Priority should be given to the selection
SV23 sanitary vortex flowmeter — SV23 is a clamp-type vortex flowmeter specially designed for the health industry. It meets food/pharmaceutical GMP requirements through a dead-angle f | Application: Application scenarios and selection: Suitable for measuring pure liquids, gases and saturated steam
SVH digital vortex street — SVH adopts an integrated cantilever beam structure and dual piezoelectric crystal redundant design. It has a wide range ratio of 20:1 and clear water | Application: It is mainly suitable for steam pipelines with risk of water hammer, wide-range processes with flow
View all 3 03 Vortex flowmeter products →
04 Electromagnetic heat meter
1 product model · Keywords: 04 Electromagnetic heat meter · SE12E
SE12E — SE12E electromagnetic heat meter is a highly integrated and cost-effective cold and heat measurement solution. It significantly simplifies the complic | Application: Whether it is central air conditioning charges for commercial buildings, heat control for industrial
View all 1 04 Electromagnetic heat meter products →
05 float flow meter
1 product model · Keywords: 05 float flow meter · SR41 metal tube float flowmeter
SR41 metal tube float flowmeter — SR41 is a variable area flow meter, mainly used to measure the unidirectional flow rate of liquid, gas and steam in closed pipes; this is a very intui | Application: Petrochemical industry: measuring aromatic hydrocarbons, alcohols, light oil and other medium and lo
View all 1 05 float flow meter products →
06 Thermal mass flow meter
2 product models · Keywords: 06 Thermal mass flow meter · ST51 pipe type · ST54 plug-in
ST51 pipe type — ST51 pipeline thermal mass flow meter is mainly used to directly measure the mass flow of gases | Application: ST51 is a high-precision, fast response, maintenance-free gas mass flow meter suitable for DN10~DN10
ST54 plug-in — ST54 is a special insertion gas mass flow meter for large diameter pipelines (DN80~2000), which can be installed/disassembled online without flow. | Application: If the pipe diameter is less than 80, use ST51, and if the pipe diameter is greater than 80, use ST5
View all 2 06 Thermal mass flow meter products →
07 Differential pressure flow meter
5 product models · Keywords: 07 Differential pressure flow meter · Orifice flow meter (SD40) · Balanced flow meter (SD41) · V-cone flow meter (SD42)
Orifice flow meter (SD40) — Standard throttling parts, simple structure, economical price | Application: Gas, vapor, liquid (single phase or mixed phase)
Balanced flow meter (SD41) — Porous rectifier, stable flow, wide measuring range, short straight pipe section | Application: High temperature and high pressure, low temperature LNG, etc.
V-cone flow meter (SD42) — Center cone rectification, anti-dirt, self-cleaning | Application: Dirty, easy to crystallize, high temperature and high pressure, gas and liquid two phases
View all 5 07 Differential pressure flow meter products →
08 Pressure transmitter
9 product models · Keywords: 08 Pressure transmitter · S3E electronic remote transmitter · S3000CD · S3000CG
S3E electronic remote transmitter — S3E = Replace "a capillary tube filled with oil" with "two counting pressure gauges + a wire", completely eliminating measurement errors caused by lon | Application: High & Large Tank liquid level measurement (High & Large Tank); Large Temperature Difference (Large
S3000CD — Differential pressure transmitter: The pressure difference between two points, such as the pressure difference before and after the filter, determines | Application: Flow measurement: orifice plate, venturi, nozzle and other throttling devices (differential pressure
S3000CG — Gauge pressure transmitter: pressure relative to atmospheric pressure, such as how much higher the pressure inside the tank is than outside (the tire | Application: Pipeline pressure: pressure monitoring of common media such as water, oil, and gas.
Container pressu
View all 9 08 Pressure transmitter products →
09 Intelligent flow controller
1 product model · Keywords: 09 Intelligent flow controller · SPC200 intelligent flow controller
SPC200 intelligent flow controller — To understand SPC200, a simple metaphor is enough: S3000 series transmitters are the "eyes and nerves", while the SPC200 is the "brain and hands". | Application: High-precision quantitative filling; batching system; process flow control; OEM equipment matching
View all 1 09 Intelligent flow controller products →
10 mass flow meter
1 product model · Keywords: 10 mass flow meter · SG61
SG61 — SG61 = A flow meter that directly measures "mass" without extrapolation. It has high accuracy, no straight pipe section requirements, and can measure | Application: Chemical industry: precise batching, reactor feeding, trade transfer