Vortex (Cyclonic) Grit Chamber

Set the flow, peak factor and water temperature — get the chamber volume and diameter from the Stokes settling velocity of 0.2 mm sand, the detention time, and the daily grit production. The compact, hydraulically-binned alternative to the horizontal grit channel in tropical headworks.

1Duty & chamber

Vortex grit bins the flow into a swirling column; heavy sand spirals to the centre hopper while organics stay in suspension. Size by peak flow and the settling velocity of the design grain.

Results — chamber & grit

Chamber volume V
Diameter D
m
Grit / day
kg/d
ItemValueBasis

2Settling check

Stokes settling of the design grain at temperature T — the vertical velocity the chamber must stay below to capture it.
ItemValueBasis

Operation envelope

ItemValueBasis

Quote the grit instruments at factory price

A vortex grit chamber still needs a magnetic flowmeter on the inlet and a level transmitter on the hopper — both in our catalogue, supplied at the manufacturer's ex-works price with the margin coming only from the export tax rebate.

Request a quote for this duty ← Headworks Primary Clarifier →
Response within 24 hours · Inputs stay in your browser — nothing is uploaded.

Sources & parameter basis

[1]METCALF & EDDY 5th ed. / WEF MOP-8 — grit chamber peaking 1.5–3×, design grain 0.2 mm, grit production 5–10 L per 1000 m³ (0.005–0.010 m³/1000 m³), side-water depth 1.0–2.0 m.
[2]Stokes law v = g(ρs−ρw)d² / (18 μ); ρs = 2650 kg/m³; μ from water viscosity at temperature T (μ≈0.798 mPa·s @ 30 °C, 1.002 @ 20 °C).
[3]Grit bulk density ≈ 1600 kg/m³ (wet). Daily mass = volume × 1600.
Full derivation and worked example: Vortex-Grit-Calculation-Sheet.md. The vortex chamber is the hydraulically-binned alternative to the horizontal grit channel — run it, then carry Q into the primary clarifier.
© 2026 Nanjing JiuYuHui Environmental Technology Co., Ltd. · jiuyuhub.com · Municipal WWTP design manual — Pre-treatment (variant).
⚠ Screening values only. Outputs from this tool are engineering screening estimates. Final equipment sizing, and any construction or permit submission, must be confirmed against the manufacturer’s verified performance curves and the applicable local regulation (e.g., Vietnam QCVN 14 / Indonesia PERMENLHK 68).