Wastewater Treatment Instrumentation

Panatilihing on target ang aeration, protektahan ang biological process, at patunayan ang compliance sa discharge point. Ang instruments sa ibaba ay sumasakop sa full measurement chain ng modern wastewater treatment plant.

Bakit Mahalaga

Ang Hamon sa Pagsukat

Sa buong Southeast Asia, ang municipal at industrial wastewater plants ay itinatayo at inu-upgrade nang mas mabilis kaysa sa local instrumentation support. Ang replacement sensors ay dumarating nang mabagal, at isang unmonitored upset ay maaaring mangahulugan ng off-spec discharge at regulatory fines.

01

Inlet & screening

Ang pH at conductivity sa inlet ay nagwa-warn ng industrial dumping bago tumama sa biological stage.

02

Aeration basin

Ang Dissolved oxygen ay nagdadrive ng blower control — ang single largest energy cost sa karamihan ng WWTPs.

03

MLSS / settling

Ang Sludge concentration ay tumutukoy sa recirculation at wasting decisions. Measured, not guessed.

04

Discharge

Ang Final pH, turbidity, at flow ay nagko-confirm ng compliance bago umalis ang tubig sa iyong site.

Field-proven selection: kami ay nag-specify ng instrumentation para sa municipal at industrial WWTPs — ang bawat model sa ibaba ay matched sa harsh conditions ng real treatment plant: humidity, chemical fumes, at 24/7 operation.

Mga Inirerekomendang Instrumento

PH6000C Online pH/ORP Monitor

pH -2 to 16 (±0.02) · ORP ±1999 mV (±5 mV) · 3 relay outputs · 144×144 panel
  • Inlet & discharge pH/ORP with configurable alarm relays for pump or dosing control
  • Compatible with multiple electrode types — swap in glass, antimony, or rugged models
  • 4-20 mA isolated output for PLC/DCS integration

DO6000Y Fluorescence Online Dissolved Oxygen

Optical (fluorescence) DO · no membrane · no electrolyte · minimal maintenance
  • No membranes or electrolyte to replace — the #1 maintenance saving in aeration control
  • Auto-cleaning option for high-fouling biological basins
  • Fast response for reliable blower trim control and energy savings

MS6000SG Online Suspended Solids / MLSS Meter

Infrared suspended solids measurement for activated sludge, return sludge, and effluent
  • Direct MLSS monitoring in the aeration and settling stages
  • Low-maintenance optical sensor, no daily cleaning required
  • Available with self-cleaning options for sticky media

SE11E Electromagnetic Flowmeter

DN2-2000 mm · ±0.2% accuracy · measures from 1 uS/cm · HART/Modbus/Profibus
  • Bidirectional flow for inlet, return activated sludge, and effluent lines
  • No moving parts — no clogging on sludge, slurry, or grit-laden water
  • IP68 option for submersible vault installations

TS600 High-Flow Peristaltic Pump

Up to 14 L/min · for polymer, flocculant, and chemical dosing
  • Self-priming, dry-run safe dosing for flocculant and coagulant feed
  • Media contacts only the tube — no valves or seals to maintain
  • Two heads in series for higher throughput on large plants

Bumubuo o nag-a-upgrade ng WWTP?

I-send sa amin ang process diagram o list of measurement points. Ire-recommend namin ang instruments, i-verify ang compatibility sa iyong PLC/DCS, at magququote sa factory-direct pricing within 24 hours sa business days.

Humiling ng Presyo