| Measured Liquid | Gas |
|---|---|
| Accuracy Class | Reading ±1.0% + full scale ±0.5% |
| Fluid Temperature | -40 ~300 °C |
| Turndown Ratio | 4.167361111 |
| Nominal Diameter Range | (10~100)mm |
| Working Pressure | 1.0MPa/1.6MPa/2.5MPa/4.0MPa/6.3MPa/Class150/Class300/others |
| Connection Material | 304 / 316L / Other |
| Probe Material | 316L / Hastelloy C / 316L+PTFE coating / High-temp ceramic |
| Connection Type | Flange type/thread type/others |
| Protection Rating | IP67 |
| Power Supply | 220VAC/24VDC |
| Signal Output | (4~20) mA / Digital pulse |
| Communication | HART/Modbus |
| Electrical Connection | 1/2-14NPT/M20×1.5 |
| Explosion-proof Type | Non-explosion-proof / flameproof |
| Structure | Integrated / split type |
| Working Environment | Ambient temp -25~60°C, humidity 5%~90% |
| Applications | Process industries, chemical, power generation, water/wastewater, oil & gas |
| Certifications | Manufactured under ISO 9001 QMS · CE/RoHS/FDA compliance varies by model (certificates available upon request) |
ST51 是面向气体测量的热式质量流量计,采用管段式(管道式)结构。探头中的两支铂电阻传感器测量被流动气体带走的热量;冷却效应与质量流量成正比,因此在额定范围内读数不受压力和温度影响。因为输出是质量,仪表不需要温度或压力补偿。
管段式安装使湿润长度短、流型稳定。10 至 100 mm 共 7 个公称口径覆盖小口径气体分配和燃烧器供气;过程连接为法兰或螺纹。仪表工作环境为 -25 至 60℃、相对湿度 5% 至 90%,防护等级 IP67,因此适用于无加热的机柜和户外机壳。
ST51 为什么是气体质量流量计而不是体积式流量计?
气体密度随压力和温度剧烈变化,体积读数会漂移。ST51 直接测量气体的质量,无需补偿,在正常运行范围内读数保持准确。
ST51 与插入式热式流量计相比最适合哪种应用?
ST51 是管段式流量计,适用 10 至 100 mm 口径,适合小口径气体分配和燃烧器供气,管段式结构使流型稳定、湿润长度短。
ST51 能否在含湿或含尘气体上使用?
含尘气体建议在探头上游加装粗过滤器;含饱和水气体应先去除液滴。探头和接液材质(316L、哈氏合金、PTFE 涂层)可根据气体化学选择。
ST51 需要直管段吗?
热式原理对流型不如差压式敏感,通常上游约 5 倍直径的短直管段即可。具体布局请参考安装手册。