| Measurement Range (set by electrode constant) | Conductivity: K=0.01: 0~20 uS·cm-1; K=0.1: 0~200 uS·cm-1; K=1.0: 0~4000 uS·cm-1; K=10.0: 0~40.0 mS·cm-1; K=30.0: 0~100.0 mS·cm-1 |
|---|---|
| TDS | K=0.01: 0~10 mg/L; K=0.1: 0~100 mg/L; K=1.0: 0~2000 mg/L; K=10.0: 0~20000 mg/L; K=30.0: 0~50000 mg/L |
| Temperature | 0~150℃ (depending on electrode configuration) |
| Resolution | Conductivity: 0.01 uS·cm-1; 0.01 mS·cm-1; TDS: 0.01 mg/L; 0.01 g/L; Temperature: 0.1℃ |
| Basic Error | Conductivity/TDS: ±1.0% F.S. ±1 digit; Temperature: ±0.5℃ |
| Auto/Manual Temp Compensation Range | 0~150℃ (reference 25℃) |
| Auto Temp Compensation Error | ±0.3% F.S. |
| Electronic Unit Stability | ±0.1% F.S. ±1 digit/24h |
| Electronic Unit Repeatability Error | ≤0.1% F.S. ±1 digit |
| Electronic Unit Alarm Error | ±1% F.S. |
| Electronic Unit Output Current Error | ±1% F.S. |
| Signal Output | 0~10 mA (load resistance <1.5 KΩ); 4~20 mA (load resistance <750 Ω); 20~4 mA (load resistance <750 Ω) |
| 2 Relay Control Contacts | 3A 240 VAC, 3A 28 VDC or 120 VAC |
| Power Supply (optional) | 85–265 VAC±10%, 50±1 Hz, power ≤3W; 9–36 VDC, power ≤3W |
| External Dimensions | 98×98×130mm |
| Installation Method | Panel mount (embedded) |
| Panel Cutout | 93×93mm |
| Instrument Weight | 0.6kg |
| Working Environment | -10~60℃; relative humidity ≤90%; no strong magnetic field interference other than the earth's magnetic field |
| Applications | Water treatment, environmental monitoring, laboratories, food & beverage, aquaculture |
| Certifications | Manufactured under ISO 9001 QMS · CE/RoHS/FDA compliance varies by model (certificates available upon request) |
Ang CON3000C ay isang siksik na panel conductivity monitor na nag-uulat ng conductivity, total dissolved solids (TDS), at temperatura mula sa iisang electrode. Sa sukat na 98 × 98 × 130 mm, panel cut-out na 93 × 93 mm, at bigat na 0.6 kg, kasya ito sa mga control cabinet at packaged skid na hindi kayang tanggapin ang karaniwang 144 × 144 mm na instrumento.
Ang measuring range ay itinatakda ng cell constant ng electrode, hindi ng transmitter. Lima ang sinusuportahang constant, mula K=0.01 (0–20 uS/cm) hanggang K=0.1, K=1.0, at K=10.0, at hanggang K=30.0 (0–100.0 mS/cm), kung saan ang TDS ay sumusunod sa parehong constant mula 0–10 mg/L hanggang 50 000 mg/L. Ang basic error ay ±1.0% ng full scale ±1 digit para sa conductivity at TDS, at ±0.5 °C para sa temperatura.
Ano ang pagkakaiba ng CON3000C sa isang 144 × 144 mm na conductivity monitor?
Pangunahin ay espasyo sa panel at bilang ng relay. Ang CON3000C ay gumagamit ng 93 × 93 mm na cut-out at may dalawang relay contact; ang mas malaking housing ay may tatlo at mas malawak na display. Ang performance ng pagsukat ay halos magkatulad.
Direkta bang sinusukat ang TDS?
Hindi. Ang TDS ay kinakalkula mula sa conductivity reading gamit ang conversion factor, kaya ang katumpakan nito ay nakadepende kung gaano kahusay tumugma ang factor na iyon sa mga dissolved solids na aktuwal na nasa inyong tubig.
Hanggang anong temperatura kayang tiisin ng electrode?
Hanggang 150 °C, depende sa configuration ng electrode na inyong pipiliin. Kumpirmahin ang rating ng cell sa pag-order, dahil magkaiba ang limitasyon ng transmitter at ng electrode.
Anong power supply ang kailangan nito?
Maaaring 85–265 VAC sa 50 Hz o 9–36 VDC, at hindi lalampas sa 3 W ang konsumo sa alinman. Angkop ang DC option para sa mga instalasyong solar-powered at mobile.
Gaano katatag ang reading sa pagitan ng mga calibration?
Ang stability ng electronic unit ay ±0.1% ng full scale ±1 digit sa loob ng 24 na oras, na may repeatability na nasa loob ng 0.1%. Sa praktika, ang drift ay nagmumula sa pagkapahid ng electrode, kaya mas mahalaga ang cleaning interval kaysa sa dalas ng calibration.